- Thermocouples
-
Resistance thermometers
- with connection head
- Resistance thermometers with explosion proof
-
Special types
- RT with special fittings
- Room resistance thermometers
- RT with hand grip for penetration
- Combination RT (resistance and glass thermometers)
- Average value probe
- Small resistance thermometer for srewing in (compact thermometer)
- Sheathed resistance thermometer with connectorless wires
- Temperature probes with magnet for surface measurement
- Measuring inserts
- Precision resistance thermometer
- Cable sensors
- Cable sensors
-
Components and accessories
- Connection heads
- Thermo junction
- Connector
- Fixing materials
- Extension protecting tubes
- Calibration block
- Miniature fixed-point cell
- Reference junction
-
Transmitter
- Transmitter for TC, 4..20mA
- Transmitter for TC, 0..10V
- Transmitter for Pt100, Pt1000, 4..20mA
- Transmitter for Pt100, Pt1000, 0..10V
- Switching transmitter for Pt100, freely configurable
- Transmitter with LCD-Display
- Analog power supply for transmitters
- Transmitter for TC, DIN-Rail mounting, 4..20mA
- Transmitter for TC, DIN-Rail mounting, 0..10V
- Transmitter for Pt100, Pt1000, DIN-Rail mounting, 4..20mA
- Transmitter for Pt100, Pt1000, DIN-Rail mounting, 0..10V
- Digital thermometer
In-head transmitter LKM 141 for thermocouples with output signal 4...20mA for mounting in connection heads form J
The LKM 141 is an analog transmitter for thermocouples according to DIN EN 60584 or DIN 43710. It converts the temperature-dependent thermoelectric voltage linearly into a standard current signal of 4...20mA. Depending on the measuring range and thermocouple type, the signal is adjusted in such a way that the temperature errors are minimized. The transmitter is designed for mounting in the measuring head form J (F). An adjustment range of approx. 200 °C (depending on the thermocouple type) is required for the span. The LKM 141 transmitter is factory calibrated to customer specifications. Subsequent fine adjustment can be carried out by means of span and zero controllers.
* depends on thermocouple
Sealing compound |
---|
Polyurethan, black |
Output |
---|
4...20mA current loop |
Sensor fracture |
---|
>20 mA |
Reaction time |
---|
< 0.1s |
Error of compensation |
---|
<±0.5°C |
Terminal type |
---|
screw terminal |
Weight |
---|
approx. 10g |
Input |
---|
Thermocouples K, J (L), T (U), N, E |
S and B with higher fault |
Range |
---|
> 200 °C* |
Zero point |
---|
> -270 °C* |
Loop voltage |
---|
10...35VDC, reverse protection |
Shorted Sensor |
---|
ambient temperature |
Permissible ripple |
---|
< 10 % |
Vibration |
---|
5g/10-200Hz |
Linearity error |
---|
<0.1% FS* |
TCR |
---|
< 100 ppm/°C |
Operating temperature range |
---|
-25 °C ... +85 °C |
Clamping range |
---|
0.13...0.75mm² |
Humidity |
---|
< 95% |
EMC emission |
---|
EN 61000-6-3:2001 |
EMC interference rejection ratio |
---|
EN 61000-6-3:2001 |
Mounting |
---|
J-head |
Dimension |
---|
25 mm x 14 mm (DxH) |