- Thermocouples
-
Resistance thermometers
- with connection head
- Resistance thermometers with explosion proof
-
Special types
- RT with special fittings
- Room resistance thermometers
- RT with hand grip for penetration
- Combination RT (resistance and glass thermometers)
- Average value probe
- Small resistance thermometer for srewing in (compact thermometer)
- Sheathed resistance thermometer with connectorless wires
- Temperature probes with magnet for surface measurement
- Measuring inserts
- Precision resistance thermometer
- Cable sensors
- Cable sensors
-
Components and accessories
- Connection heads
- Thermo junction
- Connector
- Fixing materials
- Extension protecting tubes
- Calibration block
- Miniature fixed-point cell
- Reference junction
-
Transmitter
- Transmitter for TC, 4..20mA
- Transmitter for TC, 0..10V
- Transmitter for Pt100, Pt1000, 4..20mA
- Transmitter for Pt100, Pt1000, 0..10V
- Switching transmitter for Pt100, freely configurable
- Transmitter with LCD-Display
- Analog power supply for transmitters
- Transmitter for TC, DIN-Rail mounting, 4..20mA
- Transmitter for TC, DIN-Rail mounting, 0..10V
- Transmitter for Pt100, Pt1000, DIN-Rail mounting, 4..20mA
- Transmitter for Pt100, Pt1000, DIN-Rail mounting, 0..10V
- Digital thermometer
Programmable connection head transmitter for Pt100/Pt1000 and thermocouples with a variety of output signals an an LCD Display
The LKM 154 is a free programmable transmitter for Pt100 / Pt1000 and various thermocouples with LCD display mounted in a special connection head. It converts the temperature signal linearily with high accuracy into a standard current signal or an output voltage. A battery version without an output signal is also available. The LKM 154 can be integrated with temperature sensors using an M24x1,5 connection thread to form a complete measurement module. For the range an adjustment capability of at least 20°C is required for the span. The transmitter can be configured by the customer with a separately available programming set. No readjustment is required. The output signals are also freely scalable. Via this programming set it is also possible to acquire the measurement data digitally with a PC. The different versions are identified by an additional letter.
* programmable
Protection classification |
---|
IP 65 according DIN 60529 |
Circuitry |
---|
2 wire circuit |
3 wire circuit |
4 wire circuit |
Input |
---|
Thermocouple type K |
Thermocouple type T |
Thermocouple type J |
Thermocouple type S |
Pt100 |
Pt1000 |
on inquiry |
Output |
---|
0 ... 10V |
4 ... 20mA |
Range |
---|
domain of definition of sensor, minimal 20°C * |
Zero point |
---|
as defined for the sensor* |
Resolution |
---|
0.1°C/1°C° * |
Display |
---|
LCD 5-digit, 10mm character height, rotatable |
Test current |
---|
0.2mA |
Sensor fracture |
---|
approx. 11V for voltage output |
approx. 21 mA for current loop |
Accuracy |
---|
0.2°C±1Digit for resistance sensors |
0.5°C for thermocouples |
Power supply |
---|
3.3V Lithium (CR123) |
Supply voltage |
---|
24VDC ±30% reverse protection |
Weight |
---|
approx. 290g |
Construction |
---|
U-Display and output signal 0...10V, serial interface (external voltage supply 24V) |
I-Display and output signal 4...20 mA, serial interface (voltage supply from loop) |
B-Display (voltage supply 9V battery, shutdown after 5 min.) |
Connection head |
---|
BUZH |
Measuring range |
---|
Pt100/Pt1000 -200°C ... +835°C |
Shorted Sensor |
---|
at resistance sensors approx. 0V for voltage output and approx 3 mA for current loop; |
temperature value on fracture point for thermocouples |
Permissible ripple |
---|
< 10 % |
Temperature drift |
---|
< 150 ppm/°C |
Operating temperature range |
---|
0°C ...+60°C |
Mounting |
---|
Thread M24x1.5 |
Sampling rate |
---|
>0.25/s* |
Battery operation time |
---|
>1000h on automatic switch off after 3 min * |
Features |
---|
Maximum. Minimum, Hold |
Cold-junction compensation |
---|
internal |
Interface |
---|
USB* |