Home > Components and accessories  > Digital thermometer  > Digital thermometer
Components and accessories
Digital thermometer
999 999
Bemerkung oben Test

Construction

Basic implementation

GL-implementation

GL-implementation (L max. 200 mm)

EX-implementation

EX-implementation (build in protective tube necessary)

as Resistance Thermometer

as Sheathed Resistance Thermometer

as Thermocouple

as Sheathed Thermocouple

U- Display and output signal 0...10V, serial interface (external voltage supply 24 V)

I- Display and Output 4...20 mA, serial Interface (Voltage supply from loop)

B- Display (Voltage supply 9V battery, shutdown after 5 min.)

Series K5SWZ Sensor: measuring film resistor

Type 400SWZ Sensor: ceramic or glass measuring resistor

Typ 400SWZ Sensor: measuring film resistor

clamping ring screwing

compression ring screwing

terminal screw

inside thread

straight glass thermometer

angle glass thermometer

1

2

3

on inquiry

Connection head

Form A according DIN 43 729

ball type head ø 25 of stainless steel

Form B according DIN 43 729

Form BUZ for explosion-proof design according DIN 43 729

Form B (Form BUZ for explosion-proof design) according DIN 43 729

connector GSP/GDM

Connector GSP/GDM DIN EN 175301-803

Plastic (max. 60°C ambient temperature)

Form BUS according DIN 43 729

Form F

Form F ( → accessories)

Form F according DIN 43 729

build in connector M12x1 4-pin

BUZH

on inquiry

Form

BUZ

BUS

BUZH

BUSH

Connector

Standard thermocouple plug (male)

Standard thermocouple plug box (female)

Standard thermocouple plug connection

Miniature thermocouple plug (male)

Miniature thermocouple plug box (female)

Miniature thermocouple plug connection

Round connector (e.g. LEMO connectors)

Precision connector 5-pin

Connector NS 84/85 6-pin

on inquiry

Number of pins

2

3

4

5

6

Stop flange for protective tube-ø

15

22

32

Threaded joint

adjustable with PTFE clamp ring

adjustable with metal clamp ring

adjustable with cutting ring

solderable

weldable

Material

ligth metal

gray iron

stainless steel

zinced steel

Protection classification

IP 20 according DIN 60529

IP 43 according DIN 60529

IP 54 according DIN 60529

IP 65 according DIN 60529

IP 68 according DIN 60529

suitable used connector

IP 54 (for protective tube connection with thread joint)

IP 44 (for protective tube connection with smooth borehole)

IP 53 (for protective tube connection with smooth borehole)

IP 67 according to DIN 60529 when plugged in

on inquiry

permissible tensile load

50 kN (≈ 5 Mp)

Application temperature

0 °C to 60 °C

0 °C to 100 °C

0 °C to 120 °C

0 °C to 140 °C

0 °C to 200 °C

0 °C to 300 °C

-20 °C to +70 °C

-30 °C to +80 °C

-30 °C to +85 °C

-35 °C to +100 °C

-35 °C to +180 °C

-40°C to +85°C

-40 °C to +90 °C

-40 °C to +100 °C

-40 °C to +120 °C

-40 °C to +155 °C with silicone seal

to +200°C (max. 85°C on transmitter)

whole definition range of thermocouple

for Pt: -40 °C to +140 °C

for Pt: -40 °C to +350 °C

for Ni: -40 °C to + 140 °C

for Ni: - 40 °C to + 250 °C

applicable to max. 50 K above particular fixing point temperature

applicable to max. 200 K above particular fixing point temperature

for Polyamid (PA) to 80 °C

for Polyphenylenoxid (PPO) to 120 °C

up to +380°C for GL-Design

up to +800°C

up to +1000°C

up to +1600°C

-200 up to +300°C

-200 to +600°C

-200 to +800°C

-200 to +850°C

-200 to +1000°C

-50 up to +300°C

-50 to +400°C

-50 up to +400°C (max. 120°C near the connector)

-50 up to +400°C (max. 85°C near the transmitter)

-50 up to +400°C (max. 85°C near the connector)

-200 to +850°C (dependent on resistant sensor)

on inquiry, dependent on sensor and protective tube material

on inquiry

Measuring range of transmitter

on inquiry

switching range

on inquiry

Switching temperature

on inquiry

Thermo junction

L (Fe-CuNi) DIN 43 710

J (Fe-CuNi) DIN EN 60584

K (NiCr-Ni) DIN EN 60584

N (NiCrSi-NiAl) DIN EN 60584

E (NiCr-CuNi) DIN EN 60584

T (Cu-CuNi) DIN EN 60584

S (PtRh10-Pt) DIN EN 60584

R (PtRh13-Pt) DIN EN 60584

B (PtRh30-PtRh6) DIN EN 60584

C (WRe5-WRe26)

Au-Pt DIN EN 62460

Pt-Pd DIN EN 62460

on inquiry

Number of Thermo junction

1 thermocouple

2 thermocouples

on inquiry

none

Number of temperature measuring points

1

2

3

on inquiry (≥2)

on inquiry

Temperature sensor Pt

1xPt 100 selected

Pt100

Pt10
Pt25

1xPt 100 cl. B acc. to DIN EN 60751

1xPt 500 cl. B acc. to DIN EN 60751

1xPt 1000 cl. B acc. to DIN EN 60751

1xNi 100 cl. B acc. to DIN EN 43760

Temperature sensor

1xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

1xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

2xPt 100 cl. F0,15 (old cl. A) acc. to DIN EN 60751

2xPt 100 cl. F0,3 (old cl. B) acc. to DIN EN 60751

1xPt 500 cl. F0,3 (old cl. B)  acc. to DIN EN 60751

1xPt 100 cl. B acc. to DIN EN 60751

1xPt 500 cl. B acc. to DIN EN 60751

1xPt 1000 cl. B acc. to DIN EN 60751

1xPt 100 selected

1xNi 100 cl. B acc. to DIN EN 43760

1xNi 500 cl. B acc. to DIN EN 43760

1xPt 100 cl. W0,15 (old cl. A) acc. to DIN EN 60751

1xPt 100 cl. W0,3 (old cl. B) acc. to DIN EN 60751

2xPt 100 cl. W0,15 (old cl. A) acc. to DIN EN 60751

2xPt 100 cl. W0,3 (old cl. B) acc. to DIN EN 60751

1xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751

1xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751

2xPt 100 cl. F0,3 or W0,3 (old cl. B) acc. to DIN EN 60751

2xPt 100 cl. F0,15 or W0,15 (old cl. A) acc. to DIN EN 60751

1xNi 1000 cl. B acc. to DIN 43760

Pt10
Pt25

Pt100

HL-sensor

on inquiry

Circuitry

2 wire circuit

3 wire circuit

4 wire circuit

3 wire circuit (max. 2 measuring points)

4 wire circuit (max. 1 measuring points)

3 wire circuit for 1xPt100

4 wire circuit for 1xPt100

Contact thermometer switching point

75°C

85°C

Comparison place of point of ice

ø6 x 250

Yearly stability

typ. 0,04K

typ. 0,05K

Fixed point cell

minicell with specific pure metal on inquiry

Fixed point material

Bi33In67 72,5 °C

In 156,59 °C

Sn 231,93 °C

Zn 419,53 °C

Au58In42 495,4 °C

Al67Cu33 548,2 °C

Ag88Al12 567,8 °C

Al87Si13 578,8 °C

Al 660,32 °C

Ag28Cu72 779,6 °C

on inquiry dependent on application temperature

Housing material

stainless steel

ligth metal pressure diecast

plastic Polyamid (PA)

plastic Polyphenylenoxid (PPO)

on inquiry

Case dimensions

ø12 X 4

Sealing compound

for temperature range -40 ... 80°C

for temperature range -40 ... 180°C

Sheath diameter

0.5 mm

1,0 mm

1.5 mm

2,0 mm

3,0 mm

4,5 mm

6,0 mm

on inquiry

Sheath material

1.4541

1.4571

1.4841

2.4816

on inquiry

Flange

flange design, flange dimensions as soon as flange material on inquiry

Material of the ring

Brass

on inquiry

Measuring point design

insulated of sheath

welded in sheath

insulated, integrated in fixed point cell

insulated of protective tube

connected to protective tube

disconnected bead at 2 thermocouples

connected bead at 2 thermocouples

Sheathed measuring inset diameter

6 mm

Wire size

0,35 mm

0,35 mm (TC S)

0.5 mm

0,5 mm (only for TC S)

0,5 mm (only for TC S and B)

1 mm

3 mm

3 mm (only for single design)

Handle

connector LEMOSA, up to 150°C applicable

Handle material

stainless steel

PTFE (Teflon, max. 260°C)

Protective tube form

planar

pointed 118°

with penetration point

Protective tube connection

M10x1 inside

M20x0,75 outside

Protective tube connection ød / L

15,5 / 16

22,5 / 20
32,5 / 20
M24x1,5 / 16

Protective tube material

1.0460 (C22.8)

1.4305

1.4541

1.4571

1.4749

1.4762

1.4841

C 610

C 799

2.4816

aluminium

stainless steel

Brass

at RT 1.4571

at SRT 1.4541

at SRT 1.4571

Cu tube blank

Cu tube with heat shrink hose covered ( only up to 140°C)

on inquiry

Protective tube diameter d

1

1.5

2 mm

3

3,5 mm

4 mm

4.5

6 mm

7 mm

8 mm

9 mm

11 mm

9 mm / 7 mm stepped

11 mm / 9 mm stepped

15 mm

22 mm

at RT 3 mm

at RT 3,5 mm

at RT 4 mm

at RT 4,5 mm

at RT 5 mm

at RT 6 mm

at SRT 3 mm

at SRT 4,5 mm

at SRT 6 mm

on inquiry 3 ... 6 mm

on inquiry 3 ... 10 mm

on inquiry

Protective tube length L

700 mm

on inquiry length of screwing +10 ... 1000 mm

on inquiry

Protective tube Form 4 for welding in
according DIN 43 772

Form; L1; L3; ød1; ød2; measuring insert-ø; thread
 

D1; 140; 65; 24; 12,5; 6; M18x1,5

D2; 200; 125; 24; 12,5; 6; M18x1,5

D3*; 200; 125; 30; 12,5; 8

D4; 200; 65; 24; 12,5; 6; M18x1,5

D4S*; 140; 65; 18; 9; 3; M14x1,5

D5; 260; 125; 24; 12,5; 6; M18x1,5

D6*; 255; 125; 30; 16; 8

on inquiry

Protective sleeve material

1.4571

Protective sleeve diameter

6 mm

Measuring insert diameter d

6 mm

8 mm

on inquiry

Measuring insert diameter d1/ Extension tube diameter d2

6/9

6/11

8/12

on inquiry

Sensor length L

on inquiry 30 ... 1000 mm

on inquiry at RT min 10 ... 1000 mm

on inquiry at SRT min 100 mm

2000 mm

on inquiry (length of screwing +10 ... 1000 mm)

on inquiry 50 ... 1000 mm

on inquiry 20 ... 190 mm

on inquiry 10 ... 30 mm

on inquiry min 10 mm

min. 100mm

on inquiry

Distance of the measuring points L2, L3

on inquiry

Connection design

seperate 2 wire circuit

combined 2 wire circuit

combined 4 wire circuit

on inquiry

Diameter d

12 mm

14 mm

on inquiry

Diameter d1

on inquiry

Diameter d2

on inquiry

Nominal length

255 mm + 10 mm

Nominal length L

30 mm

140 mm

160 mm

200 mm

250 mm

275 mm

320 mm

335 mm

400 mm

425 mm

500 mm

515 mm

575 mm

630 mm

645 mm

710 mm

800 mm

815 mm

1000 mm

1015 mm

1250 mm

1265 mm

1400 mm

1600 mm

2000 mm

80 mm to 160 mm

on inquiry max. 500 mm

on inquiry max. 1000 mm

on inquiry max. 2000 mm

on inquiry (up to 20 m)

on inquiry

Insert length L1

26 mm

45 mm

53 mm

63 mm

75 mm

85 mm

100 mm

160 mm

200 mm

250 mm

280 mm

80 mm to 400 mm

on inquiry 10 ... 40 mm

on inquiry min. length of thread + 10 ... 1000 mm

on inquiry from 100mm

on inquiry

extension tube length L2

60 mm

130 mm

on inquiry from 130 mm

on inquiry

Connecting lead length L2

on inquiry

Length of the connecting cable L2

1500 mm

on inquiry

Compensating cable length L2

1500 mm

on inquiry

Type of connection cable

TeSi 2xAWG24

TeSi 3xAWG26

TeSi 4xAWG26

Si(C)Si 2x0,5 mm2

Oilflex Classic 100

Te C Te 4x0.08, Cu-strand silvered

TeSi 2xAWG22
TeSi 4xAWG22

2m Cu stranded wire LifY 0,5 mm2, with low e.m.f.

on inquiry

Type of compensating cable

TGlV 2x1,5

SlSl 2x1,5

GlGlV 2x0,22

on inquiry

Cable length L2

5000 mm

on inquiry min. 100 mm

Clamping band

fixed

enclosed

Clamping range

20 - 32 mm

32 - 50 mm

50 - 70 mm

70 - 90 mm

90 - 100 mm

on inquiry

Bend protection

without

with spiral spring

Process connection

outside thread

cup nut

Construction of bajonett cap

for thread nipple (bayjonet matching part) ø12

for thread nipple (bayjonet matching part) ø14

Adjustable threaded joint

without

with

Locking ring in the screw connection

teflon clamp ring

metal clamp ring

Thread

M6

M8

M10

M10x1

M18x1,5

M20x1,5

M27x2

G1/4A

G1/2A

G3/4A

G1/2

G3/4

on inquiry M8x1 ... G1/2A

on inquiry

Thread 1

on inquiry

Thread 2

on inquiry

Thread (adjustable screw connection)

M27x2

G3/4A

on inquiry

Design

design 0 without fastener

design 1 with adjustable screwing

design 2 with additional protective tube

Connector

free ends

connector on inquiry

ø4 mm hollow plugs, gold plated

others on inquiry

Thread nipple

none

on inquiry

Input

Pt100, 2 wire circuit

Pt100, 2-, 3 wire circuit

Pt100/Pt1000, 2 wire circuit

Pt100/Pt1000, 2-/3 wire circuit

Pt100/Pt1000, 2-/3-/4 wire circuit

Pt100/1000, Ni100/1000 as soon as other resistance sensors, sensor replaceable

thermocouple K, J(L), T(U), N, E;

S B with higher fault

thermocouple K, J, T, L, U;

S, B with higher fault

thermocouple K, J, T, L, U, N, E;

S, B with higher fault

thermocouples type K NiCr-Ni
( miniature thermocouple female connector )

Themocouple types K, T, J, S
(adusted by manufacturer)

Pt100

Pt1000

Thermocouple Typ K

Thermocouple Typ T

Thermocouple Typ J

Thermocouple Typ S

Pt100, 4 wire circuit

Pt1000, 3 wire circuit

Pt100 permanently connected

on inquiry

Circuitry

2 wire circuit

3 wire circuit

4 wire circuit

Input voltage

230VAC

Input frequency

50 ... 60Hz

Input fuse

100 mA fast-acting (extern)

Kind of connection

4 wire circuit

Output

short-circuit-proof

0 ... 10V

0...10V short-circuit-proof

4 ... 20mA

4...20mA current loop

Output voltage

24VDC

Output resistance

min. 3 kΩ

Nominal current

400mA

Continuous rating

max. 9,6VA

Ripples

< 10mV

Stability

< 1% (full load)

Transformer

VDE 0551, EN 60742

Testing voltage

5000V~

Measuring range

-100°C ... +1370°C

Pt100 -200°C..845°C

Pt1000 -50..400°C

Ni100 -60..230°C

Ni1000 -60..230°C

resistance range 1 0..380W

resistance range 2 0..2,500 kW

Type K -200°C ... +1370°C

Type T -200°C ... +400°C

Type J -200°C ... +1200°C

Type S 0°C ... +1760°C

Pt100 -200 ... +830°C

P1000 -50C ... +400C

-20°C ... +110°C

on inquiry

Typ K -200°C ... +1370°C

Typ T -200°C ... +400°C

Typ J -200°C ... +1200°C

Typ S 0°C ... +1760°C

Pt100/Pt1000 -200°C ... 835°C

Measuring range of transmitter

on inquiry for design I or U

Range

> 20°C*

> 200°C*

20°C ... 850°C*

domain of definition of sensor, minimal 20°C *

Zero point

> -270°C*

-200°C ... +600°C*

as defined for the sensor*

Resolution

0.01°C

1°C

0.1°C/1°C° *

0.01°C

Display

LCD 4-digit, 11mm character height

LCD 3 1/2-digit, 12.7mm caracter hight

LCD 5-digit, 10mm caracter height, rotatable

Loop voltage

10...35VDC, reverse protection

Test current

0.8 ... 1mA*

0.2mA

Sensor fracture

>20 mA

>10V

like high temperature

approx. 11V for voltage output

approx. 21 mA for current loop

Shorted Sensor

<4 mA

ambient temperature

ambient temperature

0V

like low temperature

room ambient temperature

ambient temperature

at resistance sensors approx. 0V for voltage output and approx 3 mA for current loop;

Temperature value on fracture point for thermocouples

Auxiliary supply

24V DC ±10%, reverse protection

Permissible ripple

< 10 %

Reaction time

< 0.1s

Vibration

5g/10-200Hz

Insulation voltage

1 kV

Measuring error

typ. <0.5°C max. 0.8°C

Linearity error

<0.1% FS

<0.1% FS*

<1% FS*

Error of compensation

<±0.5°C

Switching current

max. 5A

switching range

16 ranges between -200°C ... 480°C

Switching precision

<1%

Contact rating

150W / 1250VA

Switching voltage

30VDC, 250VAC

TCR

<50ppm/°C

<100ppm/°C

Messgenauigkeit

0,5°C±1Digit

Accuracy

-100°C... -50°C: 1% FS

-50°C...1100°C: 0.5% FS

1100°C...1350°C: 3% FS

± 0.03°C ± 1 Digit

0.5 °C ±1Digit

<1% FS

0.5% FS

0.2°C±1Digit for resistance sensors

0.5°C for thermocouples

0.2°C ±1Digit for resistance sensors

0.5°C for thermocouples

Temperature drift

<150ppm/°C

Linearization accuracy

± 0,02°C

System accuracy

without sensor typ. <0,06°C

Female connector

Binder 719 4-polig

Operating temperature range

-25°C ... +70°C

-25°C ... +85°C

0°C ... +50°C

0°C ... +60°C

0°C ... +70°C

Operating temperature of transformer

-40 °C ... +85 °C

Terminal type

screw terminal

Clamping range

0.13...1.5mm²

0.2...2.5mm²

0.13...0.75mm²

Humidity

< 95%

EMC emission

EN 61000-6-3:2001

EMC interference rejection ratio

EN 61000-6-3:2001

Mounting

35mm DIN rail

B-Head

J-head

Thread M24x1.5

Working resistance

approx. 700Ω at 24V

Current consumtion

max. 10 mA

max. 40 mA

2.4 mA

max. 20mA

Power supply

9 Volt battery, 6F22

6mA out from interface

3.3V Lithium (CR123)

Supply voltage

15...35V DC reverse protection

21 ... 27 VDC / 15mA

24VDC ±10%

24VDC ±30% reverse protection

Sampling rate

maximum 1/s *

maximal 4/s

approx. 3/s

3/s

>0.25/s*

Battery operation time

>500h at 1/s

~2000h

>1000h on automatic switch off after 3 min *

Features

Maximum, Minimum, Hold

Case

EMG25-LG

Case material

Polycarbonat

unbreakable polyamide

ABS black

Case dimension (HxWxD)

75 x 25 x 53 mm

123 x 72,5 x 27,5 mm

32 x 58 x 16mm

Dimension

25mm x 14 mm (DxH)

25mm x 15mm (DxH)

44mm x 26,5mm (DxH)

44mm x 26,7mm (DxH)

79.5 x 40 x 84mm (HxWxD)

60 x 120 x 26mm ( BxHxT )

total length

250 mm

on inquiry

Sealing compound

Polyurethan, black

Weight

approx. 10g

approx. 23g

approx. 30g

approx. 40g

approx. 60g

approx. 130g

approx. 290g

approx. 420g

Connector

female connector M8

Miniatur thermocouple  socket

Pt100 Binder 719 4-pole

Pt1000 Binder 719 3-pole

Interface

RS232**

USB**

USB

cold-junction compensation

internal

Storage temperature

-40°C ...100°C

-20°C ... +80°C


Kurzbeschreibung Test
04/2018 technical changes are reserved
Request

Last Updated: