Home > Product cataloque > Product overview > Components and accessories  > Transmitter  > Transmitter for TC, 0..10V
Components and accessories
Transmitter
Transmitter LKM 102
LKM 102
aditional pictures:

Anschlussbelegung    

In-Head Transmitter LKM 102
Thermocouples, B-head, 0..10V, 24V supply voltage

The LKM 102 is an analogue transducer for thermocouples acc. DIN EN 60584 or DIN 43713.
The temperature-sensitive voltage will be transformed voltage-linearly into a voltage output of 0..10V.
The transducer LKM 102 is to be mounted inside the protection head type B. The working range of the instrument needs a span of at least 200°C. The transducer LKM 102 is tuned within a customized span ex works. Further fine-tuning can be arranged by adjusting zero and span.

 

Input

thermocouple K, J(L), T(U), N, E;

S B with higher fault

Output

0...10V short-circuit-proof

Range

> 200°C*

Zero point

> -270°C*

Loop voltage

10...35VDC, reverse protection

Sensor fracture

>10V

Shorted Sensor

ambient temperature

Permissible ripple

< 10 %

Reaction time

< 0.1s

Vibration

5g/10-200Hz

Linearity error

<1% FS*

Error of compensation

<±0.5°C

TCR

<100ppm/°C

Operating temperature range

-25°C ... +85°C

Terminal type

screw terminal

Clamping range

0.13...1.5mm²

Humidity

< 95%

EMC emission

EN 61000-6-3:2001

EMC interference rejection ratio

EN 61000-6-3:2001

Mounting

B-Head

Current consumtion

max. 10 mA

Supply voltage

15...35V DC reverse protection

Dimension

44mm x 26,5mm (DxH)

Sealing compound

Polyurethan, black

Weight

approx. 30g


* dependent upon thermocouple

11/2016 technical changes are reserved
Request